tel: 310-325-1043 fax: 310-325-1044 www.mpsind.com sales@mpsind.com pp20a series ? power rating up to 100 watts ? high effciency ? footprint 20.12 mm x 18.50 mm ? lower profle of 7.4 mm ? high isolation (operational) 1500 vdc ? high frequency 200 khz C 700 khz ? operating temperature -40oc to +125oc ? custom design available electrical parameters @25c part number pp20a- primary inductance (h min) leakage inductance (h max) dc resistance (m max) turns ratio isolation (v dc ) figure primary secondary primary secondary a aux 0601 58 0.30 15 55 0.6//0.6 6t 1t // 1t 1500 a 0602 58 0.30 15 55 0.6+0.6 6t 1t+1t 1500 a 0603 58 0.30 15 55 2.00 6t 3t 1500 b 0606 58 0.30 30 110 8.00 6t 6t 1500 c 0608 58 0.25 30 110 12.0 6t 8t 1500 c 0610 58 0.25 30 110 18.0 6t 10t 1500 c 1201 230 0.90 55 180 0.6//0.6 12t 1t // 1t 1500 a 1202 230 0.90 55 180 0.6+0.6 12t 1t+1t 1500 a 1203 230 0.90 55 180 2.00 12t 3t 1500 b 1206 230 0.70 110 360 8.00 12t 6t 1500 c 1208 230 0.70 110 360 12.0 12t 8t 1500 c 1210 230 0.70 110 360 18.0 12t 10t 1500 c product performance is limited to specifed parameters. data is subject to change without prior notice. planar transformers high frequency 100 watt application of configuration application of configuration part number pp20a- v in v out / i out part number pp20a- v in v out / i out 0601 18 C 36 vdc 1.2v@55.0a --1.8v@50.0a 1201 36 C 75 vdc 1.2v@55.0a --1.8v@50.0a 0602 18 C 36 vdc 2.5v@34.0a -- 3.3v@30.0a 1202 36 C 75 vdc 2.5v@34.0a -- 3.3v@30.0a 0603 18 C 36 vdc 5.0 v @ 20 a 1203 36 C 75 vdc 5.0 v @ 20 a 0606 18 C 36 vdc 8.0v@12.5a -- 10v@10.0a 1206 36 C 75 vdc 8.0v@12.5a -- 10v@10.0a 0608 18 C 36 vdc 12v@8.33a -- 15v@6.67a 1208 36 C 75 vdc 12v@8.33a -- 15v@6.67a 0610 18 C 36 vdc 16v@6.25a -- 18v@5.56a 1210 36 C 75 vdc 16v@6.25a -- 18v@5.56a notes: 1. the inductance is measured in primary windings pin (2-5). 2. the leakage inductance is measured in primary winding pin (2 -5) with all other windings shorted.
tel: 310-325-1043 fax: 310-325-1044 www.mpsind.com sales@mpsind.com product performance is limited to specifed parameters. data is subject to change without prior notice. dimensions unless otherwise specifed, all tolerances are: inch: .xx : 0.015 .xxx : 0.004 mm: x,x : 0,38 x,xx : 0,10 dimensions (mm) schematics figure a figure b figure c suggested pad layout pp20a series planar transformers high frequency 100 watt
|